Used topcon, ct80 noncontact computerized tonometer. The ls 80 offers alerts for heights, out of range and low battery situations. Topcon ct 80 non contact tonometer, cable and pdf manual. Slope control key zoom in topcon logo menu elevation control key zoom out. Examwriter does not send data to the topcon ct 80 equipment the topcon ct 80 equipment interface saves equipment data to the examwriter database, which then can be accessed by all computers networked to look at that database. This tonometer ct80 is a precision electrical device for medical use that must be used under the instruction of a doctor. Download citation noncontact tonometers topcon ct 60 and ct 80 and goldmann applanation tonometry objective. Adjusted tono value is reference value not available in all countries, please check with your distributor for availability in your country. Fda status of medical devices for glaucoma screening. Download free topcon user manuals, owners manuals, instructions, warranties and installation guides, etc. The system converts your article files to a single pdf file used in. Topcon link software supports all proprietary topcon and sokkia file formats as well as a number of industry formats. User maintenance to maintain the safety and performance of the equipment, never attempt to do maintenance on your own.
To access the topcon logo menus, tap the topcon logo in the far right corner. Ankersmit historical representation pdf download download. Topcon ct 80 noncontact computerized tonometer tonometer for sale. Adobe acrobat reader is needed to view pdf formatted files.
Topcon multitool ct80 users manual free pdf download. Page 1instruction manual computerized tonometer ct 80 page 2 introduction thank you for purchasing the topcon computer ized tonometer ct 80. Thank you for purchasing the topcon computerized tonometer ct 80. The ap tonometer used was a topcon ct80 model topcon corporation, tokyo, japan. Ls80 laser accessory topcon positioning systems, inc. The topcon ct80 takes its original measurement method using two sensors. Request pdf assessment of the accuracy and reliability of the topcon ct80 noncontact tonometer the reliability of noncontact tonometers has been. The acp8em chart projector features 30 charts including etdrs, with fastest chart rotation on the market including high quality display screen. To study the relationship among topcon non contact tonometers, models ct 80. Topcon logo key the topcon logo key at the top right corner of the main screen displays a popup bar of four menus. Read and download topcon multitool multitool ct 80 users manual page 59 online. Serial cables must be purchased from topcon prior to integration. You can purchase serial cables and serialtousb adapter cables from topcon at 1. Consult topcon europe medicals entire ct80 ct80a, noncontact.
Ct80 also applies to ct60 the topcon ct80 computerized noncontact tonometer brings quick and accurate tonometry readings to your fingertips. When the air puff applanates the cornea, a light sensor detects the applanation moment, while at. Dual sensor system topcon s accurate measuring system the topcon ct 80 takes its original measurement method using two sensors. Effect of central corneal thickness on intraocular. It features a 30% faster measurement time, a triple patient safety function, and a dual sensor measuring system. Ct80 ct80a, noncontact tonometer topcon europe medical. When the air puff applanates the cornea a light sensor detects the applanation moment, while at the same time another sensor monitors the internal chamber to obtain the intraocular pressure. Any format can be converted to desired topcon and sokkia format for export to topcon and sokkia instruments.
In our study, topcon ct80 was applied for nct measurement. The ct1 1p is equipped with a builtin thermal printer that can be easily loaded with a roll of paper. Topcon multitool ct80 users manual page 59 free pdf. To get the best use from the instrument, please carefully read these instructions and keep this instruction manual in a convenient location for future reference. Each subjects intraocular pressure was assessed with each technique on two separate occasions, one week. The topcon acp8em chart projectors provide sharp image and image projection with a fast chart disk rotation. Summary of contents of user manual for topcon ct 80. This used topcon ct80 non contact autotometer is in perfect working condition and comes with a full parts and labor warranty. Comparative evaluation of intraocular pressure with an airpuff. Ct80 noncontact computerized tonometer topcon medical.
Many files can also be converted between third party and proprietary formats. The enlarged projection size of 330x270 leaves a clear and wide view. It displays a warning message on the monitor when a lens is dirty, and also which lens it is the measurement glass or the chamber glass. Topcon ct 1p topcon ct 20 topcon ct 40 topcon ct 60 topcon ct 80 topcon ct 800 image systems capturing6 alcon b scan alcon ocusan haagstreit slitlamps cn 9007 haagstreit slitlamp im 9007 konan specular microscope righton coolpix slitlamp software quantel medical a scan quantel medical b scan with special thanks to our partners topcon. The ct 800 non contact tonometer, is able to calculate adjusted intraocular pressure based on pachymetry values manually. It serves to import multiple industrystandard file formats such as autodesk dwgdxf and bentley microstation dgn files. The compact footprint and design of topcon s ct 800 saves space and adds functionality to the contemporary eye care practice. Introductionthank you for purchasing the topcon computerized tonometer ct 80. The ct800 is able to calculate adjusted tono value from measured iop to manually input the corneal thickness value measured by other devices such as a pachymeter. Assessment of the accuracy and reliability of the topcon ct80 non. Consult topcon europe medicals entire ct80 ct80a, noncontact tonometer. The ct80 lets the operator know in advance when maintenance is needed.
Ct 80a 80 accurate measuring system dual sensor system the topcon ct 80a 80 incorporates an original measurement method using two sensors. O ct80 permite uma operacao mais facil e mais rapida porque conta com uma nova. Pacoima, ca 931 pcon ct 80 specifications measuring range 0. Examwriter receives data from the topcon ct 80 equipment and displays the data on the examwriter chart window. Before connecting a personal computer to the topcon product. The ct80 computerized tonometer makes intraocular pressure measurements easier and more comfortable than ever before. Files data are then converted and available for export to any of the topcon machine control formats tp3, tn3, rd3, ln3, pt3, etc. Topcon wants me to ship the thing in, was hoping for. Magnet office 3d exchange is a file conversion and data preparation application for the construction market. Builtin printer the ct80 features a builtin printer that provides a hardcopy of all stored iop data at the touch of a button. When the air puff applanates the cornea, a light sensor detects the applanation moment, while at the same time another sensor monitors.
Ct80a ct80 060 mm hg 030 mm hg 060 mm hg selezionabile 11 mm tv monitor screen. If you have any questions, please contact me before buying. The topcon ct 80 computerized tonometer brings quick and accurate tonometry readings to your fingertips. Used topcon ct80 non contact tonometer nct precision. Introduction thank you for purchasing the topcon computerized tonometer ct 80. It makes a louder chunk sound now when you hit the button but doesnt blow any air. The ct 1 1p cuts the paper automatically at the end of printing. For more information please refer to online user manual. Topcon europe was established in 1970 to coordinate the sales and marketing activities of topcon products in europe. Used topcon ct80 non contact auto tonometer, used ct80 nct. Topcon ct 80 mode demploi anglais topcon trc50ex mode demploi. It provides exactly the information needed at the leveling stave. To compare intraocular pressure iop measurements obtained with the topcon ct. Read and download topcon multitool multitool ct 80 users manual online.
Marketing 111 bauer drive oakland, nj 07436 ct 80 rebate promo dec 20 expires december 31, 20 this rebate must be used towards the purchase of new topcon instrumentation only, from topcon medical systems, inc. Ask our serviceman for repair except for the items specified here which can be maintained by the user. Topcon laser hand receivers are rugged, water and dust resistant and used with most conventional rotating lasers. Assessment of the accuracy and reliability of the topcon.
The reichert at550 automated non contact tonometer, refurbished and certified by vision systems inc. To get the best use from the instrument, please carefully. Adobe acrobat reader is distributed freely by adobe systems. Using the topcon ct 80 interface ensure that the topcon ct 80 is connected to the computer that examwriter is installed upon with a serial cable or serialtousb adapter cable.